Hydraulic Turn
Clamp Cylinder

HDSZ

  • For medium and large presses
  • For clamping upper and lower dies
  • For dies with lock plate, U-recess or T-slot
  • Fixed installation in press slide or press bed

Mode of operation

  • A single-acting hydraulic cylinder with spring return supplies the clamping movement.
  • A double-acting hydraulic cylinder provides rotation.

Description

A hydraulic rotation unit turns the tie rod head 90°. Then, the clamping cylinder executes the clamping stroke. The sequence of movements is controlled internally. In order to secure the clamping force, hydraulic pressure must be maintained (e.g. with pilot-controlled check valves).

Pressure monitoring by the pressure switch on the hydraulic power pack is required. To unclamp, the tie rod is lifted off the die by means of a return spring. Rotation occurs via the hydraulic rotation unit.

  • Fully automated operation
  • Large clamping dimension tolerance
  • Simple monitoring of functions by proximity switches
  • Minimal installation investment
  • Pratically maintenance free
  • High clamping force and small dimensions
  • Only two hydraulic connections required
  • Tie rod can be turned by hand

  • Pilot-controlled check valves
  • Flow control valves
  • Fittings
  • Hydraulic hoses / Hydraulic accessories
  • Hydraulic power packs
  • Limit switches / cable

Technical data

Type HDSZ-63 HDSZ 100 HDSZ 160
Clamping force [kN] /
at operating pressure [bar]
63 / 400 100 / 400 160 / 400
max. loading force [kN] 1 75 125 200
max. operating pressure [bar] 400
Clamping dimension tolerance [mm] +/- 2
Stroke {mm} 6
Oil volume: Clamp / unclamp [cm3] 14 / 14 19 / 4 31 / 6
Max. oil volume flow [l/min] 2) 1,2
Limit switch:Number / type
Supply voltage
Connection type
Designation
· two inductive proximity switches
· 10-30 V DC
·Plug-intype(M8x1),cablelengthapprox.0,2m
·Tie rod unclamped and rotated to unclamped
position S1
· Tie rod rotated in clamping position S2
max. operating temperature [°C] 70
Weight [kg] 11 15 22,5

1* Mechanical damage may occur at higher loads. 2* If a pump with a greater output is used, the oil flow must be reduced by means of flow-control valves or one-way restrictors.

Fixing is achieved with four screws, DIN EN ISO 4762 , strength class 10.9 (not included).