Flexible
Clamp System
EVK with ZSF
- For medium and large presses
- For various die dimensions
- For clamping upper dies
- For dies with U-recesses and standardised clamping dimensions
- Suitable for retrofitting
Mode of operation
- The electric positioning unit moves the spring clamp unit along the T-slot.
- A single-acting spring clamp cylinder generates the clamping force.
- Unclamping of the spring clamp units is effected hydraulically.
Description
The electric positioning unit moves the spring clamp unit by means of a chain. For clamping, the clamp unit is depressurized so that the springs generate the clamping force. Hydraulic pressure is required for unclamping and for positioning of the clamp units. Therefore, pressure control by means of a pressure switch on the hydraulic power pack is necessary. The electric positioning units may be switched off individually by the machine control so that these clamp units remain in their park position, where they are clamped.
- Clamping of different die sizes
- Short clamping time
- Clamping force is generated mechanically by springs
- Displacementpathupto1000mmavailable
- Allimportantfunctionselectricallymonitored
- High automation level
- Central operation
- Fittings
- Hydraulic hoses / hydraulic accessories
- Hydraulic power packs
- Limit switches / cable
- Plug connectors
Technical data
| Verschiebeeinheit | EVK | ||
| Motor: Art Betriebsspannung |
Gleichstrom 24V |
alternativ | Drehstrom 400V 50 HZ |
| Motorleistung [W] | 8 | 90 | |
| Verschiebungsgeschwindigkeit [mm/s] | 150 | 145 | |
| Endschalter: Art Betriebsspannung Bezeichnung |
• induktive Näherungsschalter • PNP-Schließer; 10-30 V DC • Spannelement in Parkposition S1 • Spannelement am Werkzeug S2 • Ende des Verschiebeweges (optional) S5 |
||
| Steckverbindung | Han® 25 D Han® 6 E (zusätzlich bei Drehstromantrieb) |
||
| Clamp Unit | ZSF 100 |
| Clamping force [kN] | 100 |
| max. loading force [kN] 1) | 125 |
| Clampingdimensiontolerance[mm] | +/- 0,5 |
| Stroke [mm] | 5 |
| Unclamp pressure / max. unclamp pressure [bar] |
300 / 320 |
| Oil volume: Unclamp [cm³] | 20 |
| max. operating temperature[°C] | 70 |
| Weight [kg] | 26 |
1) Mechanical damage may occur at higher load.
Fixing is achieved with four hexagon head screws with flange (DIN 6921), M10x30, strength class 8.8 and two spring dowel pins (DIN1481) Ø8x20 (not included).