Flexible
Clamp System
EVK with HKZ
- For medium and large presses
- For various die dimensions
- For clamping upper dies
- For dies with U-recesses
- Suitable for retrofitting
Mode of operation
- The electric positioning unit moves the T-bolt clamp along the T-slot.
- A single-acting hydraulic cylinder generates the clamping force.
- Unclamping is effected by spring load with the operating pressure switched off.
Description
The electric positioning unit moves the T-bolt clamp by means of a chain. Hydraulic pressure is applied to the T-bolt clamp to generate the clamping force. The hydraulic pressure must be maintained to secure the clamping force (e.g. with pilotcontrolled check valves). Therefore, pressure control by means of a pressure switch on the hydraulic power pack is necessary.
The electric positioning units may be switched off individually by the machine control so that these clamp units remain in their park position, where they are clamped.
- Clamping of different die sizes
- Large clamping dimension tolerance
- Short clamping time
- Displacement path up to 1000 mm available
- Clamping in the park position possible
- All important functions electrically monitored
- High automation level
- Central operation
- Pilot-controlled check valves
- Fittings
- Hydraulic hoses / hydraulic accessories
- Hydraulic power packs
- Limit switches / cable
- Plug connectors
Technical data
| Positioning Unit | EVK | ||
| Motor: Type Supply voltage |
DC 24V |
alternatively | three-phase 400V 50 HZ |
| Motor power [W] | 8 | 90 | |
| Positioning speed [mm/s] | 150 | 145 | |
| Limit switches: Type Switch voltage Designation |
• Inductive proximity switches • PNP normally open; 10-30V DC • Clamp unit in park position S1 • Clamp unit at the die S2 • End of displacement path (optional) S5 |
||
| Plug connector | Han® 25 D Han® 6 E (additionally for three-phase drive) |
||
| Clamp Unit | HKZ 104 |
| Clamping force [kN] / at operating pressure [bar] |
104 / 400 |
| max. loading force [kN] 1) | 130 |
| max. operating pressure [bar] | 400 |
| Clamping dimension tolerance [mm] | +/- 4 |
| Stroke [mm] | 12 |
| Oil volume: Clamp [cm³] | 31 |
| max. operating temperature[°C] | 70 |
| Weight [kg] | 16 |
1) Mechanical damage may occur at higher load.
Fixing is achieved with four hexagon head screws with flange (DIN 6921) M10x30, strength class 8.8 and two spring dowel pins Ø8x20(not included).